Cabinet-type perfluorohexanone fire extinguishing devices generally consist of cabinets, cylinder groups, control valves, nozzles and other components. Because perfluorohexanone fire extinguishing agent has a low fire extinguishing concentration and good environmental performance, cabinet-type perfluorohexanone fire extinguishing devices have become the main alternative to traditional hydrofluorocarbon gas fire extinguishing devices. There are many models of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles, which are suitable for different scenarios. Lanzhong can also provide customized services for perfluorohexanone fire extinguishing nozzles according to customer needs.

Cabinet-type perfluorohexanone fire extinguishing devices generally consist of cabinets, cylinder groups, control valves, nozzles and other components. Because perfluorohexanone fire extinguishing agent has a low fire extinguishing concentration and good environmental performance, cabinet-type perfluorohexanone fire extinguishing devices have become the main alternative to traditional hydrofluorocarbon gas fire extinguishing devices. There are many models of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles, which are suitable for different scenarios. Lanzhong can also provide customized services for perfluorohexanone fire extinguishing nozzles according to customer needs.


北京柜式全氟己酮灭火喷头型号


1. Beijing cabinet type perfluorohexanone fire extinguishing nozzle model

The application scenarios of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles are different, so the specifications and sizes of the nozzles are different, and the model is composed of the main specifications and parameters of the nozzle. Different models of cabinet-type perfluorohexanone fire-extinguishing nozzles can meet the use of different scenarios. The following is the general selection table of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles:

1. QPT120/4.2, flow coefficient k=120, working pressure is 4.2MPa, interface thread size is Rp1 1/4, commonly used materials are 6061/HPb59/304

2. QPT140/4.2, flow coefficient k=140, working pressure is 4.2MPa, interface thread size is Rp1 1/4, commonly used materials are 6061/HPb59/304

3. QPT160/4.2, flow coefficient k=160, working pressure is 4.2MPa, interface thread size is Rp1 1/2, commonly used materials are 6061/HPb59/304

4. QPT180/4.2, flow coefficient k=180, working pressure is 4.2MPa, interface thread size is Rp1 1/2, commonly used materials are 6061/HPb59/304

5. QPT200/4.2, flow coefficient k=200, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304

6. QPT220/4.2, flow coefficient k=220, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304

7. QPT240/4.2, flow coefficient k=24, working pressure is 4.2MPa, interface thread size is Rp2, commonly used materials are 6061/HPb59/304

2. Beijing cabinet type perfluorohexanone fire extinguishing nozzle parameters

The parameters of cabinet-type perfluorohexanone fire extinguishing nozzles are crucial to the normal operation and fire-extinguishing effect of the fire protection system. Correct selection of the nozzle model, size, working pressure, spray angle, spray mode and material suitable for specific application scenarios can confirm that the nozzle can respond quickly when a fire occurs and effectively extinguish the fire, ensuring the safety of people and property. Therefore, when designing and installing a fire protection system, the parameters of cabinet-type perfluorohexanone fire extinguishing nozzles should be carefully considered and configured to confirm the stability and effectiveness of the system.

The following are the main parameters of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles:

1. Nozzle model: The model of cabinet-type perfluorohexanone fire extinguishing nozzles is usually specified by the manufacturer and is used to identify and distinguish different types of nozzles. Different types of sprinkler heads may have different spray characteristics and fire extinguishing effects, so it is important to correctly select the model suitable for a specific application scenario.

2. Nozzle size: The size of cabinet-type perfluorohexanone fire extinguishing nozzles is usually used to describe its spray range and liquid flow rate. Sizes are generally in inches, and common sizes include 1/2 inch, 3/4 inch, etc. As needed, the appropriate nozzle size can be selected to meet the fire extinguishing agent requirements of the fire protection system.

3. Nozzle working pressure: The working pressure of cabinet-type perfluorohexanone fire extinguishing nozzles refers to the pressure range required under normal operating conditions. The setting of the working pressure should comply with the design requirements of the fire protection system, and confirm that the sprinkler head can spray fire extinguishing agent normally and effectively extinguish the fire.

4. Spray angle of the nozzle: The spray angle of the cabinet-type perfluorohexanone fire extinguishing nozzle determines its spray range and coverage area. Common spray angles include 60 degrees, 90 degrees, etc. You can choose the appropriate angle according to your needs to ensure that the fire area is covered in multiple aspects.

5. Nozzle spray mode: The spray mode of cabinet-type perfluorohexanone fire extinguishing nozzles can be divided into several different types such as spray, jet and direct flush. Different spray patterns are suitable for different fire types and application scenarios. Choosing the right spray pattern can improve fire extinguishing effectiveness and safety.

6. Nozzle material: The material of cabinet-type perfluorohexanone fire extinguishing nozzles is crucial to its performance and durability. Common nozzle materials include stainless steel, brass, etc. Appropriate material selection can ensure that the nozzle will not be corroded and damaged during long-term use and maintain stable working performance.

3. Characteristics of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles

Beijing cabinet-type perfluorohexanone fire extinguishing nozzle is a new type of fire extinguishing device, which uses advanced perfluorohexanone fire extinguishing agent and has the following outstanding features:

1. High efficiency fire extinguishing: Perfluorohexanone fire extinguishing agent has excellent fire extinguishing performance, can quickly extinguish the fire source, effectively control the spread of fire, and reduce the losses caused by fire.

2. Highly safe: Perfluorohexanone fire extinguishing agent is non-toxic, odorless and colorless, will not cause harm to human health, and is environmentally friendly and will not cause damage to the atmospheric ozone layer.

3. Quick response: The sprinkler head adopts advanced temperature detection technology, which can quickly identify the fire source and activate the fire extinguishing device, shortening the fire extinguishing response time and enhancing the fire extinguishing effect.

4. Intelligent control: The sprinkler head has a built-in intelligent control system, which can adjust the injection volume of fire extinguishing agent in real time according to the fire situation, thereby maximizing the fire extinguishing efficiency.


北京柜式全氟己酮灭火喷头


4. Application of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles

Beijing cabinet-type perfluorohexanone fire extinguishing nozzles are widely used in various industries and places, especially suitable for the following fields:

Commercial buildings: Shopping malls, office buildings, hotels and other crowded places can respond to sudden fires promptly and effectively to protect people's lives and property.

Industrial plants: Chemical, electric power, manufacturing and other industries have strong fire extinguishing capabilities for high-risk fire sources, effectively reducing fire risks.

Transportation: Transportation hubs such as subways, airports, and stations can respond quickly and put out fires to ensure the safe travel of passengers.

Warehousing and logistics: Warehouses, logistics centers and other places can quickly control the spread of fire and reduce material losses.

5. The role of Beijing cabinet-type perfluorohexanone fire extinguishing nozzles in fire safety:

Beijing cabinet-type perfluorohexanone fire extinguishing nozzles play an important role in fire safety, specifically in the following aspects:

1. Improve fire extinguishing efficiency: Perfluorohexanone fire extinguishing agent has high efficiency fire extinguishing performance, can quickly extinguish the fire source, reduce the spread of fire, and minimize the losses caused by fire.

2. Enhance fire extinguishing response speed: The temperature detection technology enables the sprinkler head to quickly identify the fire source, activate the fire extinguishing device, shorten the fire extinguishing response time, and effectively control the development of fire.

3. Ensure personnel safety: Perfluorohexanone fire extinguishing agent is non-toxic and harmless, and can confirm the safety of personnel at the fire scene while reducing the harm of fire smoke to the human body.

4. Reduce environmental pollution: Perfluorohexanone fire extinguishing agent is environmentally friendly and will not cause damage to the atmospheric ozone layer, effectively reducing the impact of the fire extinguishing process on the environment.

With its excellent performance and innovative design, Beijing cabinet-type perfluorohexanone fire extinguishing nozzles provide an efficient, safe and intelligent solution for fire protection. Its wide range of applications and important role in fire safety make Beijing cabinet-type perfluorohexanone fire extinguishing nozzles a stable partner in protecting people's lives and property. In the future, with the continuous development of science and technology, it is believed that Beijing cabinet-type perfluorohexanone fire extinguishing nozzles will play a more important role in the field of fire prevention and control and make positive contributions to building a safe and sustainable society.