Open nozzle

High pressure water mist open nozzle

Word:[Big][Middle][Small] QR Code 2022/8/22     Viewed:    

高压细水雾开式喷头


The high-pressure water mist open nozzle contains one or more nozzles, consisting of the nozzle body, nozzle holder, nozzle, diversion device and filter. Under a certain water pressure, water is atomized by mechanical means such as centrifugation, impact or jet. Compared with other nozzles with the same flow rate, this nozzle has good water mist uniformity, less flow resistance loss, and greater initial kinetic energy and diffuseness.

High pressure water mist open nozzle price:

Unit price: 100 yuan/piece

Lanzhong Electromechanical has the ability to design and produce various forms of nozzles, and can customize the structural type, flow coefficient and material according to customer needs. We will quote based on the design and production difficulty of the nozzle as well as the order quantity, and provide wholesale supply. Large quantity and good price. Welcome to buy!

High pressure water mist open nozzle model specifications:

The parameters involved include model, structural form, flow coefficient, minimum working pressure, maximum working pressure and number of nozzles. The following is a selection table for conventional high-pressure water mist open sprinklers:

model Structural form Flow coefficient minimum working pressure highest working pressure Number of nozzles
XSW-TQ0.3/10 A/B/C 0.3 10Mpa 14Mpa 5/6/7
XSW-TQ0.5/10 A/B/C 0.5 10Mpa 14Mpa 5/6/7
XSW-T0.7/10 A/B/C 0.7 10Mpa 14Mpa 5/6/7
XSW-T0.9/10 A/B/C 0.9 10Mpa 14Mpa 5/6/7
XSW-T1.0/10 A/B/C 1 10Mpa 14Mpa 5/6/7
XSW-T1.2/10 A/B/C 1.2 10Mpa 14Mpa 5/6/7
XSW-T1.5/10 A/B/C 1.5 10Mpa 14Mpa 5/6/7
XSW-T1.7/10 A/B/C 1.7 10Mpa 14Mpa 5/6/7
XSW-T2.0/10 A/B/C 2 10Mpa 14Mpa 5/6/7
XSW-T2.5/10 A/B/C 2.5 10Mpa 14Mpa 5/6/7
XSW-T3.0/10 A/B/C 3 10Mpa 14Mpa 5/6/7
XSW-T3.5/10 A/B/C 3.5 10Mpa 14Mpa 5/6/7
XSW-T4.0/5 A/B/C 4 5Mpa 10Mpa 5/6/7
XSW-T4.5/5 A/B/C 4.5 5Mpa 10Mpa 5/6/7
XSW-T5.0/5 A/B/C 5 5Mpa 10Mpa 5/6/7
XSW-T5.5/5 A/B/C 5.5 5Mpa 10Mpa 5/6/7

High-pressure water mist open nozzle customization:

In addition to the above conventional models and parameters of high-pressure water mist open nozzles, our company has the ability to design and produce other forms of high-pressure water mist open nozzles. Customers can provide structural types, flow coefficients and materials for customization. Customization of high-pressure water mist open nozzles requires at least the following information:

● Nozzle structure type, such as appearance size, thread, structure, etc.;

●Media;

● Flow coefficient;

● Performance requirements, such as droplet diameter, range, spray angle, installation parameters, etc.;

● Minimum and maximum working pressure;

● Application place and working environment;

● Material;

Principles for the layout of high-pressure water mist open sprinklers:

The spacing between high-pressure open water mist nozzles should not be greater than 4m. When the area of ​​the protection area exceeds 500 square meters, the partition application method should be adopted. For local application of water mist systems, the water mist should be sprayed directly onto the object to be protected, and its protection area should be determined based on its outer surface area. When used outdoors, the impact of wind speed on water mist should be evaluated and the sprinkler heads should be appropriately encrypted.

High pressure water mist open nozzle size:

Conventional high-pressure water mist open nozzle sizes are 3 minutes, 4 minutes, 6 minutes, and 1 inch.

It is mainly used in flammable and explosive hazardous places, such as hydraulic stations, lubricating oil depots, turbine oil depots, oil-immersed power transformers, diesel generator rooms, boiler rooms and other flammable liquid fire hazardous places, and electrical fire hazardous places such as cable tunnels, large cable rooms, computer rooms, etc. Conventional high-pressure water mist open nozzles can also be used in important document storage places, such as libraries, archives, and reference rooms where important documents are stored.