fire sprinkler nozzle
The gas fire extinguishing nozzle is one of the important components of the gas fire extinguishing system. Its function is to confirm that the fire extinguishing agent is ejected in a specific jet form, prompting the fire extinguishing agent to quickly vaporize and reach the fire extinguishing concentration in the protected space. Its fire extinguishing efficiency is high and the fire extinguishing speed is fast.
Gas fire sprinkler model:
Commonly used models of gas fire sprinklers include: DN15, DN20, DN25, DN32, DN40, DN50, etc., which can meet basic application needs. In addition, Lanzhong Electromechanical can also be customized, and only needs to provide relevant parameters of the nozzle. The following is a selection table for conventional gas fire sprinklers:
Nozzle specification code NO
Overall dimensions (mm)
Nozzle without spray hood
Nozzle with spray hood
H
H
2
0.8
1.98
15
60
60
3
1.2
4.45
60~74
60~77
4
1.6
7.94
5
2
12.39
6
2.4
17.81
7
2.8
24.26
8
3.2
61.68
9
3.6
40.06
10
4.0
49.48
11
4.4
59.87
12
4.8
71.29
13
5.2
83.61
60~95
60~95
14
5.6
96.97
15
6.0
111.29
16
6.4
126.71
18
7.2
160.32
20
8.0
197.94
22
8.8
239.48
24
9.6
285.03
Gas fire sprinkler price:
Unit price: 100 yuan/piece
Lanzhong Electromechanical has the ability to design and produce various forms of nozzles, and can customize the structural type, flow coefficient and material according to customer needs. We will quote based on the design and production difficulty of the nozzle as well as the order quantity, and provide wholesale supply. Large quantity and good price. Welcome to buy!
Customized gas fire sprinkler heads:
The appearance, size, flow coefficient, material, etc. of gas fire sprinklers can be customized. Lanzhong Electromechanical has the ability to design and produce various forms of sprinklers, and can customize the structural type, flow coefficient, and materials according to customer needs. Customers need to provide at least the following information when customizing gas fire sprinklers:
(1) Structural type of nozzle, such as appearance size, thread, structure, etc.;
(2) Medium;
(3) Flow coefficient;
(4) Performance requirements, such as droplet diameter, range, spray angle, installation parameters, etc.;
(5) Minimum and maximum working pressure;
(6) Application site and working environment;
(7) Material.
Gas fire sprinkler function:
From a broad perspective, gas fire extinguishing systems can extinguish electrical fires, gas fires, liquid fires and solid surface fires; from a narrow perspective, gas fire extinguishing systems can extinguish computer rooms, UPS rooms, generator rooms, transformer and distribution rooms, archives, cultural relics, art galleries, bank vaults, government financial institutions, valuable equipment rooms and other places.
1. Electrical fire;
2. Solid surface fire;
3. Liquid fire;
4. Gas fires where the gas source can be cut off before extinguishing the fire.
Note: Except for cable tunnels (mezzanines, wells) and self-contained generator rooms, K-type and other types of hot aerosol prefabricated fire extinguishing systems shall not be used for other electrical fires.
![]()
Gas fire sprinkler installation specifications:
1. The protection height and protection radius of the nozzle should comply with the following regulations:
a. The maximum protection height should not be greater than 6.5m;
b. The minimum protection height should not be less than 0.3m;
c. When the installation height of the nozzle is less than 1.5m, the protection radius should not be greater than 4.5m;
d. When the installation height of the sprinkler head is not less than 1.5m, the protection radius should not be greater than 7.5m.
2. The nozzle should be installed close to the top surface of the protective area, and the maximum distance from the top surface should not be greater than 0.5m.
3. When installing nozzles, the model, specifications and nozzle hole direction should be checked one by one according to the design requirements, and the quantity should be checked to avoid lack of quantity affecting the construction progress.
4. For nozzles without decorative covers installed under the suspended ceiling, the threads at the end of the connecting pipe should not be exposed on the suspended ceiling; for nozzles with decorative covers installed under the suspended ceiling, the decorative cover should be close to the suspended ceiling.